Installing Sensor Heads - Omron ZX-T Operation Manual

Zx-t series smart sensors
Hide thumbs Also See for ZX-T:
Table of Contents

Advertisement

Section 2
PREPARATIONS FOR MEASUREMENT

Installing Sensor Heads

This section describes how to install Sensor Heads and Preamplifiers.
Secure the connector so that it is not subjected to vibration or shock.
Sensor Heads
Installation
Mounting Jig
ZX-TDS01T/TDS04T-@
Mount the Sensor Head using M3 screws and a mounting torque between 0.6 and
0.8 N·m.
1.50
ZX-TDS10T-@@
Mount the Sensor Head using M4 screws and a mounting torque between 2 and 3 N·m.
ZX-T
26
Operation Manual
Do not clamp the Sensor Head directly on the end of the screw. Otherwise, the Sensor Head may
be damaged.
10
26
18
2
A
A
42
3.50
A
M3
Two, 3.50 dia.
Material: Aluminum
8
18
A
Recommendation: Misumi Corp.
M4
4.5
Two, 4.5 dia.
Cross-section
View A-A
Material: Aluminum
10
30
Recommendation: Misumi Corp.
Unit: mm
Model: SHSTA6-20
Unit: mm
Model: SHSTA8-20

Advertisement

Table of Contents
loading

Table of Contents