PG-D2/PG-X2
There are 5 V and 12 V PG power supplies.
Check the PG power supply specifications before connecting.
The maximum response frequency is 300 kHz.
Use the following equation to computer the output frequency of the PG (f
A separate power supply is required if the PG power supply capacity is greater than 200 mA. (If momentary
power loss must be handled, use a backup capacitor or other method.)
-38
2
Motor speed at maximum frequency output (min
f
(Hz) =
PG
PG-X2
TA1
IP12
IG
IP5
A (+)
A (-)
B (+)
B (-)
Z (+)
Z (-)
IG
TA3
Fig 2.30 PG-X2 Connection Example (for 12 V PG power supply)
60
PG power
supply
AC
0V +12V
1
0 V
2
Capacitor for
+12 V
3
momentary
+
power loss
+
4
PG
-
5
+
6
-
7
8
9
10
).
PG
−1
)
× PG rating (p/rev)