Set the number of data specified using command messages as quantity of specified messages x 2. Handle
response messages in the same way.
INFO
Data Tables
The data tables are shown below. The types of data are as follows: Reference data, monitor data, and broadcast
data.
Reference Data
The reference data table is shown below. You can both read and write reference data.
Register No.
0000H
Not used
Frequency reference
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
0001H
Bit 7
Bit 8
Bit 9
Bit A
Bit B
Bit C
Bit D
Bit E
Bit F
0002H
Frequency reference (Set units using constant o1-03)
0003H
Not used
0004H
Torque reference
0005H
Torque compensation
0006H
PID target value
0007H
Analog output 1 setting (-11 V/-1540 to 10 V/1540)
0008H
Analog output 2 setting (-11 V/-1540 to 11 V/1540)
Multi-function contact output setting
Bit 0
Bit 1
Bit 2
Bit 3
0009H
Bit 4
Bit 5
Bit 6
Bit 7
Bits 8 to F
000AH to 000EH Not used
Contents
Run/stop command
1: Run 0: Stop
Forward/reverse operation
1: Reverse 0: Forward
External fault
1: Error (EFO)
Fault reset
1: Reset command
ComNet
ComCtrl
Multi-function input command 3
Multi-function input command 4
Multi-function input command 5
Multi-function input command 6
Multi-function input command 7
Multi-function input command 8
Multi-function input command 9
Multi-function input command 10
Multi-function input command 11
Multi-function input command 12
Contact output (terminal M1-M2)
Contact output (terminal M3-M4)
Contact output (terminal M5-M6)
PHC3(Contact P3-C3)
1: ON 0: OFF
PHC4(Contact P4-C4)
1: ON 0: OFF
Not used
Set error contact (terminal MA-MC) output using bit 7. 1: ON 0: OFF
Error contact (terminal MA-MC)
Not used
Individual Functions
1: ON 0: OFF
1: ON 0: OFF
1: ON 0: OFF
1: ON 0: OFF
87