Zero Servo: b9
User constants for dwell functions are shown in the following table.
Name
Con-
stant
Display
Number
Zero-servo
Adjust the strength of the
gain
zero-servo lock.
Enabled when the "zero-servo
command" is set for the
multi-function input. When
the zero-servo command has
been input and the frequency
b9-01
reference drop below excita-
Zero Servo
tion level (b2-01), a position
Gain
control loop is created and the
motor stops. Increasing the
zero-servo gain in turn
increases the strength of the
lock. Increasing it by too
much will cause oscillation.
Zero-servo
Sets the output width of the
completion
P-lock completion signal.
width
Enabled when the "zero-servo
completion (end)" is set for a
multi-function input. The
zero-servo completion signal
is ON when the current posi-
b9-02
tion is within the range (the
zero-servo position + zero-
Zero Servo
servo completion width.)
Count
Set the allowable position dis-
placement from the zero-
servo position to 4 times the
pulse rate of the PG (pulse
generator, encoder) in use.
Setting
Factory
Description
Range
Setting
0 to
100
0 to
16383
Control Methods
Change
Open
during
V/f
Loop
Opera-
V/f
with
Vec-
tion
PG
tor
1
5
No
No
No
No
10
No
No
No
No
User Constant Tables
MEMO
Open
BUS
Flux
Loop
Page
Regis-
Vec-
Vec-
ter
tor
tor
2
A
No
1DAH
A
No
1DBH
5-
19