Fault History: U3
User constants for the error log are shown in the following table.
Con-
stant
Number
Most recent
fault
U3-01
Last Fault
Second most
recent fault
U3-02
Fault Mes-
sage 2
Third most
recent fault
U3-03
Fault Mes-
sage 3
Fourth/oldest
fault
U3-04
Fault Mes-
sage 4
Cumulative
operation
time at fault
U3-05
Elapsed Time
1
Accumulated
time of sec-
ond fault
U3-06
Elapsed Time
2
Accumulated
time of third
fault
U3-07
Elapsed Time
3
Accumulated
time of
fourth/oldest
U3-08
fault
Elapsed Time
4
Note The following errors are not recorded in the error log: CPF00, 01, 02, 03, UV1, and UV2.
-82
5
Name
Description
Display
The error contents of 1st
previous fault.
The error contents of 2nd
previous fault.
The error contents of 3rd
previous fault.
The error contents of 4th
previous fault.
The total operating time
when the 1st previous fault
occurred.
The total operating time
when the 2nd previous fault
occurred.
The total operating time
when the 3rd previous fault
occurred.
The total operating time
when the 4th previous fault
occurred.
Output Signal Level
Min.
During Multi-Function
Unit
Analog Output
-
-
-
-
1
(Cannot be output.)
hr
1
hr
1
hr
1
hr
Control Methods
MEMO
Open
Open
BUS
V/f
Loop
Flux
-loop
Regis-
V/f
with
Vec-
Vec-
Vec-
PG
tor
tor
tor
1
2
A
A
A
A
A
90H
A
A
A
A
A
91H
A
A
A
A
A
92H
A
A
A
A
A
93H
A
A
A
A
A
94H
A
A
A
A
A
95H
A
A
A
A
A
96H
A
A
A
A
A
97H
ter