Inverter Protection; Performing Overheating Protection On Mounted Braking Resistors - Omron VARISPEED G7 Instruction Manual

Hide thumbs Also See for VARISPEED G7:
Table of Contents

Advertisement

Inverter Protection

This section explains the functions for protecting the Inverter and the braking resistor.

Performing Overheating Protection on Mounted Braking Resistors

Perform overheating protection on Inverter-mounted braking resistors (Model: ERF-150WJ
When overheating in a mounted braking resistor is detected, an alarm RH (Mounted braking resistor overheat-
ing) is displayed on the Digital Operator, and the motor coasts to a stop.
Related Constants
Con-
stant
Number
L8-01
Multi-function Contact Outputs (H2-01 to H2-05)
Set-
ting
Value
D
Braking resistor fault (ON: Resistor overheat or braking transistor fault)
INFO
-64
6
Name
Description
Display
Protect selec-
tion for internal
0: Disabled (no overheating
DB resistor
protection)
(Type ERF)
1: Enabled (overheating
protection)
DB Resistor
Prot
The most likely causes of RH (Mounted braking resistor overheating) being detected are that the deceleration
time is too short or that the motor regeneration energy is too large. In these cases, lengthen the deceleration
time or replace the Braking Resistor Unit with one with a higher breaking capacity.
Setting
Factory
Range
Setting
0 or 1
0
Function
).
Control Methods
Change
Open
during
V/f
Flux
Loop
Opera-
V/f
with
Vec-
Vector
tion
PG
tor
1
No
A
A
A
A
Control Methods
Open
V/f
Loop
Flux
V/f
with
Vec-
Vec-
PG
tor
1
Yes
Yes
Yes
Yes
Open
Loop
Vector
2
A
Open
Loop
Vec-
tor
tor
2
Yes

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents