Omron V600 User Manual page 95

V600 series rfid system
Hide thumbs Also See for V600:
Table of Contents

Advertisement

SET INFORMATION READ (UL)
This command is used to read the settings of the Hand-held Reader Writer.
Only the Auto Command OFF function is supported by the V600-CHUD.
The settings made with the COMMUNICATIONS CONDITIONS SETTING (TR) command are not valid for the V600-
CHUD.
Command
Command
code
Terminator
U
L
CR
2
2
Response
Command
code
End code
Settings for TR command
U
L
0
0
T
R
2
2
End code
Indicates the execution result for the command.
00: Normal completion
For details on end codes, refer to End code List.
Settings for TR command Baud rate
Data length
Parity
Stop bits
Settings for FN command Auto Command OFF Specification
Normal Operation Output Specification 0: Normal Operation Output used.
System data
SI000000
×
×
×
×
:
F
Data
Stop
length
bits
Baud
Parity
Auto Command
rate
OFF specification
Hand-held Reader Writer system data
S
I
p.95
Settings for
FN command
×
×
N
:
Normal
Operation
Output
specification
Terminator
0
0
0
0
0
0
8
0: 9,600 bps
1: 2,400 bps
2: 4,800 bps
3: 19,200 bps
4: 38,400 bps
0: 7 bits
1: 8 bits
0: Even parity
1: Odd parity
2: No parity
0: 2 bits
1: 1 bit
0: Auto Command OFF used.
1: Auto Command OFF not used.
1: Normal Operation Output not used.
Section 3
Commands
CR
2
RFID System
93
User's Manual