Omron V600 User Manual page 87

V600 series rfid system
Hide thumbs Also See for V600:
Table of Contents

Advertisement

EXPANSION BATCH FILL (fl)
This command writes specified data for the number of write bytes starting from the specified write start
address. Up to 2 Kbytes of data can be written in a batch.
Command
Processing
area
Write area
Command
Data
number
start address
code
setting
setting
×
×
f
l
H
1
2
1
1
Data setting
Always H.
Processing area number
Always 1.
setting
Write area start address
Specifies the start address of the area in the Data Carrier to be written to in 4-digit hexadecimal
code.
Setting range: 0000h to 1FFFh
Number of write bytes
Specifies the data to be written to the Data Carrier in 4-digit hexadecimal.
Setting range: 0001h to 0800h
Specified data
Indicates the data to be written to the Data Carrier.
Response
Command
code
End code
Terminator
f
l
0
0
CR
2
2
2
End code
Indicates the execution result for the command.
The end code 00 indicates normal completion.
For details on end codes, refer to End code List.
Number of
write bytes
×
×
×
×
×
×
4
4
p.95
Specified
Terminator
data
×
×
CR