Omron V600 User Manual page 38

V600 series rfid system
Hide thumbs Also See for V600:
Table of Contents

Advertisement

Section 2
Communications Preparations
•Reset Procedure
1.
Turn ON the power while pressing the reset button.
2.
Keep the reset button depressed for two seconds or more. The green operation indicator will start
flashing.
3.
With the green operation indicator flashing, remove your finger from the reset button and press the acti-
vate switch.
4.
When the activate switch is pressed, the operation indicator will stop flashing green. This indicates that
all of the settings have been initialized.
Note: If the activate switch is not pressed within 30 seconds from the time that the operation indicator
starts flashing green, the settings will not be initialized.