Using the OVERWRITE COUNT Command
Example: When the three bytes from address 0010H are used as the overwrite count area.
1. The overwrite count initial value of
100,000 times is written in the control
area.
"WTH10010"
0010
0011
0012
3. The accumulated count is 100,000 times.
When "MDS1001000" is executed, it will be "MD76" (overwrite count exceeded.)
0010
0011
0012
2. Enter the overwrite count of 5.
"MDS1001005"
01
H
86
H
A0
H
00
H
00
H
00
H
A total of 5 times will be decremented from
100,000.
01
0010
86
0011
9B
0012
Section 4
Functions
H
H
H
RFID System
User's Manual
107