Degree
4
Protection against water
spray
5
Protection against water jet
spray
6
Protection
against
pressure water jet spray
7
Protection underwater
8
Protection underwater
Protection
Protects against water spray
approaching at any angle
towards the product.
Protects against water jet
spray approaching at any
angle towards the product.
high
Protects against high-pres-
sure water jet spray approach-
ing at any angle towards the
product.
Resists the penetration of
water when the product is
placed underwater at speci-
fied pressure for a specified
time.
Can be used continuously
underwater.
Test method (with fresh water)
Water is sprayed at any
angle towards the product
for 10 min from the test
machine.
Water is jet sprayed at any
angle towards the product
for 1 min per square meter
for at least 3 min in total
from the test machine.
Discharging nozzle: 6.3 dia.
Water is jet sprayed at any
angle towards the product
for 1 min per square meter
for at least 3 min in total
from the test machine.
Discharging nozzle: 12.5 dia.
The product is placed 1 m
deep in water (if the prod-
uct is 850 mm max. in
height) for 30 min.
The test method is deter-
mined by the manufac-
turer and user.
Section 6
Appendices
Water rate is 0.07 liter/min
per hole.
2.5 to 3 m
2.5 to 3 m
1 m