Omron V600 User Manual page 89

V600 series rfid system
Hide thumbs Also See for V600:
Table of Contents

Advertisement

OVERWRITE COUNT CONTROL (MDS)
This command is used to control the number of overwrite operations performed by EEPROM Data Car-
riers. This command determines whether the EEPROM overwrite count has been exceeded when the
specified number of overwrites is subtracted from the specified overwrite count control area data.
Command
Processing
area
Command
Mode
number
setting
code
Area start address
setting
×
×
M
D
S
1
2
1
1
4
Mode setting
Always S.
Processing area number
Always 1.
setting
Area start address
Specifies the start address of the overwrite count control area in 4-digit hexadecimal.
Setting range: 0000h to 1FFDh
Decrement count
Specifies the number of refresh operations in 2-digit hexadecimal.
Setting range: 00h to FFh (00 = Performs overwrite count check only)
For details, refer to Data Carrier Service Life Detection.
Set the start address between @@@0H and @@@5H or between @@@8H and @@@DH. If the start address is set
between @@@6H and @@@7H or between @@@EH and @@@FH, an address error (error code: 7A(HEX)) will be
returned in the end code.
Response
Command
code
End code
Terminator
M
D
0
0
C R
2
2
2
End code
Indicates the execution result for the command.
00: Normal completion
76: Data error warning
For details on end codes, refer to End code List.
For details on controlling the overwrite count, refer to Data Carrier Service Life Detection.
p.105
Decrement
count
Terminator
×
×
×
×
CR
2
2
p.105
p.95
Section 3
Commands
RFID System
87
User's Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V600-chudV600-ch1d-v2

Table of Contents