Section 4
Functions
Hand-held Reader Writer Functions
Multiple Area Control
The Hand-held Reader Writer can read and write across several non-consecutive Data Carrier
memory areas (10 areas max.) at one time. To use this feature, the number of control areas is
specified using the NUMBER OF CONTROL AREAS command. ASCII and hexadecimal code can be
used simultaneously for the one command control, but reading and writing cannot be performed
simultaneously.
Example: Data in the Following 3 Areas are Read
Area (1): Address
Area (2): Address
Area (3): Address
Command R D A 3 0 0 1 0 0 5 H 0 0 3 0 0 2 H 0 0 3 5 0 3 * CR
Response
Refer to Command and Response Format for more details on ASCII and hexadecimal codes.
RFID System
98
User's Manual
0010H
Number of bytes
05 bytes
Code setting
ASCII
0030H
Number of bytes
02 bytes
Code setting
Hexadecimal
0035H
Number of bytes
03 bytes
Code setting
Hexadecimal
R D 0 0 O M R O N 1 2 3 4 3 1 3 2 3 3 * CR
Area (1) Area (2)
p.44
Area (1)
Area (2)
Area (3)
Area (3)
0010H
4
F
"O"
0011H
4
D
"M"
0012H
5
2
"R"
0013H
4
F
"O"
0014H
4
E
"N"
0030H
1
2
0031H
3
4
0035H
3
1
0036H
3
2
0037H
3
3