Omron V600 User Manual page 82

V600 series rfid system
Hide thumbs Also See for V600:
Table of Contents

Advertisement

Section 3
Commands
EXPANSION BATCH BUTTON AUTO READ (ur)
After this command is received by the Hand-held Reader Writer, up to 2 Kbytes of data will be read
from the Data Carrier in a batch when the activate switch is pressed after the Hand-held Reader Writer
moves close to the Data Carrier. The Hand-held Reader Writer responds when communications
between the Hand-held Reader Writer and Data Carrier have ended.
Command
Command
Data
code
setting
u
r
A/H
2
1
Data setting
Processing area number
setting
Read area start address
Number of read bytes
Response
Command
code
End code
0
u
r
2
End code
Read data
RFID System
80
User's Manual
Processing
area
Read area
number
start address
setting
×
×
×
×
×
1
1
4
Sets the code format used to send responses for read data.
A: ASCII
H: Hexadecimal code
Always 1.
Specifies the start address of the area in the Data Carrier to be read from in 4-digit hexadecimal
code.
Setting range: 0000h to 1FFFh
Specifies the number of bytes to be read from the Data Carrier in 4-digit hexadecimal.
The maximum number of bytes that can be read at one time is 2,048 bytes.
Setting range: 0001h to 0800h
•ASCII: 2,048 bytes (2,048 characters)
•Hexadecimal code: 2,048 bytes (4,096 characters)
×
×
×
×
0
2
n
Indicates the execution result for the command.
The end code 00 indicates normal completion.
For details on end codes, refer to End code List.
p.95
Indicates the data read from the Data Carrier.
The characters in ASCII indicate the number of read bytes and the characters in hexadecimal code
indicate the number of read bytes x 2.
Number of
Terminator
read bytes
×
×
×
CR
4
2
Terminator
CR
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V600-chudV600-ch1d-v2

Table of Contents