Section 3
Commands
BASIC FUNCTIONS SETTING (FN)
This command is used to set the Auto Commands OFF function and Normal Operation Output func-
tion. The Hand-held Reader Writer must be restarted to make the changes take effect.
Only the Auto Command OFF function is supported by the V600-CHUD. The Normal Operation Output function is not
supported by the V600-CHUD.
Command
Auto
Command
OFF
specification
Command
code
F
N
1
2
1
Auto Command OFF
specifications
Normal Operation Out-
put Specification
Response
Command
code
End code
F
N
0
2
End code
RFID System
92
User's Manual
Normal
Operation
Output
Terminator
specification
1
CR
1
2
Designates whether the Auto Command OFF function is used.
0: Auto Command OFF used.
1: Auto Command OFF not used.
Default setting: Auto Command OFF used.
Designates whether the Normal Operation Output is used.
0: Normal Operation Output used.
1: Normal Operation Output not used.
Default setting: Normal Operation Output used.
Terminator
0
CR
2
2
Indicates the execution result for the command.
00: Normal completion
For details on end codes, refer to End code List.
p.95