Omron V600 User Manual page 101

V600 series rfid system
Hide thumbs Also See for V600:
Table of Contents

Advertisement

Auto Command OFF Function
If communications with the Data Carrier do not begin within one minute after an auto command or
button auto command is sent from the host device to the Hand-held Reader Writer after entering the
Data Carrier wait status, the Auto Command OFF function automatically aborts the auto command and
returns a "Data Carrier non-existent" error (error code 72) to the host device. When the Auto
Command OFF function is not used, the auto command will not be aborted even if one minute passes
after entering the Data Carrier wait status.
This function is set using the BASIC FUNCTIONS SETTING (FN) command.
Refer to the section on the BASIC FUNCTIONS SETTING (FN) command for details on the setting method.
p.92
Normal Operation Output Function
When the Hand-held Reader Writer is operating normally, this function turns ON the Data Set Ready
(DS) output to allow the host device to monitor the operating status of the Hand-held Reader Writer.
This function is set using the BASIC FUNCTIONS SETTING (FN) command.
The Normal Operation Output function cannot be used with the V600-CHUD.
Refer to section on the BASIC FUNCTIONS SETTING (FN) command for details on the setting method.
p.92
Section 4
Functions
RFID System
99
User's Manual