Button Commands
Button commands used to perform communications with the Data Carrier are activated when the acti-
vate switch is pressed after commands are sent from the host device, and the antenna end of the
Hand-held Reader Writer has been moved close to the Data Carrier.
Host device
1. A command is sent from the host device to the Hand-held Reader Writer. As a result, the operation
indicator will light green.
2. Move the antenna end of the Hand-held Reader Writer close to the Data Carrier.
3. Press the Hand-held Reader Writer activate switch.
4. The Hand-held Reader Writer communicates with the Data Carrier.
5. A response is returned to the host device from the Hand-held Reader Writer.
If communications are normal, the operation indicator (LED) lights green and then turns OFF.
If the Data Carrier is not detected within the Hand-held Reader Writer's communication area when the
activate switch is pressed, a Data Carrier Non-existent Error will occur.
At this time, the operation indicator will flash red.