COMMUNICATIONS CONDITIONS SETTING (TR)
This command is used to set serial communications parameters. The Hand-held Reader Writer must
be restarted to make the changes take effect.
The COMMUNICATIONS CONDITIONS SETTING (TR) command can be used only with the V600-CH1D-V2.
Do not use it with the V600-CHUD.
Command
Command
Baud
Data
Parity
Stop
code
rate
length
bits
T
R
1
1
1
1
2
1
1
1
1
Baud rate
Sets the baud rate.
0: 9,600 bps
1: 2,400 bps
2: 4,800 bps
3: 19,200 bps
4: 38,400 bps
Default setting: 9,600 bps
Data length
Sets the data length.
0: 7 bits
1: 8 bits
Default setting: 7 bits
Parity
Sets the parity.
0: Even parity
1: Odd parity
2: No parity
Default setting: Even parity
Stop bits
Sets the number of stop bits.
0: 2 bits
1: 1 bit
Default setting: 2 bits
Response
Command
code
End code
Terminator
T
R
0
0
CR
2
2
2
End code
Indicates the execution result for the command.
00: Normal completion
For details on end codes, refer to End code List.
Terminator
CR
2
p.95
Section 3
Commands
RFID System
91
User's Manual