Omron TJ2-MC64 - PROGRAMMING Programming Manual page 284

Hide thumbs Also See for TJ2-MC64 - PROGRAMMING:
Table of Contents

Advertisement

Examples and tips
The table below lists the available functions which can be allocated to the
CN1 input signals.
/i
Signal name
Symbol
Disabled
---
Forward drive prohibition input
POT
Reverse drive prohibition input
NOT
Emergency Stop Input
STOP
External Latch Input 1
EXT1
External Latch Input 2
EXT2
Origin Proximity Input
DEC
External Latch Input 3
EXT3
Forward External Torque
PCL
Limit Input
Reverse External Torque
NCL
Limit Input
Monitor Input 0
MON0
Monitor Input 1
MON1
Monitor Input 2
MON2
For more information on the CN1 I/O connector pins on the Servo Drivers,
refer to the specific Servo Driver manual.
Servo Driver inputs that are mapped into the Trajexia I/O space like this are
accessed within the program per axis and cannot be accessed in the usual
way with the IN command. The only way you can use these inputs in the
program is to assign them to the axis parameters DATUM_IN, FHOLD_IN,
FWD_IN and REV_IN. The inputs of the axis Servo Driver are used,
depending on the axis of which the parameters are set.
PROGRAMMING MANUAL
Set value
NO
NC
00h
Setting not available
01h
81h
02h
82h
14h
94h
20h
Setting not available
21h
Setting not available
22h
A2h
28h
Setting not available
2Ch
ACh
2Dh
ADh
2Eh
AEh
2Fh
AFh
30h
B0h
278