One solution is:
UNITS = 2 = 65536
Pn202 = 3
Pn203 = 5
The calculation of the multiturn limit setting parameter Pn205 is not needed
in this case because the ball screw is a system with a fixed (limited) axis. It is
enough to set this value large enough to have the overflow of the counter out
of the effective position. Also, because of the axis is finite, it is not important
to set the REP_OPTION parameter, because REP_DIST must be set large
enough so it is outside of the maximum effective position (540 mm). One
solution is: REP_DIST = 1000 and REP_OPTION = 0.
With these setting, executing MOVE(17) moves the ball screw 17 mm in
forward direction.