Comparison With Previous Versions Of The Configurator - Omron 3G8F5-DRM21-E - V2 Operation Manual

Devicenet configurator ver. 2; isa board; pcmcia card
Table of Contents

Advertisement

Introduction
1-1-8

Comparison with Previous Versions of the Configurator

Item
Basic configuration/operations
Network connection
Supported
OMRON masters
DeviceNet
masters
Slave remote I/O allocations
Master remote I/O
communications settings
Slave remote I/O
communications settings
Enabling or disabling device
data checks in remote I/O
communication
Explicit message monitoring
timer list settings
COS/Cyclic heart beat timer
settings
I/O comment settings (for
slave I/O data)
Monitor
Display of list of data on net-
functions
work devices
Unit status monitoring
Slave function monitoring
Storage
Network configuration files
functions
Device parameter files
EDS files
Compact flash memory
10
The following table lists the difference in function between version 1.20 and
version 2.@ of the Configurator.
Version 2.@
Dragging and dropping offline make
it possible to create a virtual network
(for display) in the Configurator.
Each device (Master or slave) can
also be set online.
• Dedicated ISA Board
• Dedicated PCMCIA Card
• From the COM port of the computer
to the serial port of the PLC. (Pos-
sible with CS/CJ-series PLCs only.)
• From the Ethernet port of the com-
puter to the Ethernet Unit of the
PLC. (Possible with CS/CJ-series
PLCs only.)
CS1W-DRM21, CJ1W-DRM21,
CVM1-DRM21-V1 or C200HW-
DRM21-V1
Note Output is possible in file for-
mats compatible with open
network controllers or NX-
Servers for DeviceNet.
Possible with CS/CJ-series PLCs
only.
Possible with CS/CJ-series PLCs
only.
Possible with CS/CJ-series PLCs
only.
Possible with CS/CJ-series PLCs
only.
Possible with CS/CJ-series PLCs
only.
Possible with CS/CJ-series PLCs
only.
Possible
Possible
Possible with CS/CJ-series PLCs
only.
Possible
Possible (extension: .npf)
Possible (extension: .dvf)
Possible (extension: .eds)
Stored in compact flash memory and
downloaded to the master. (Possible
with CS/CJ-series PLCs only.)
Section 1-1
Version 1.20
Each device must be set online,
except the scan list of the master.
• Dedicated ISA Board
• Dedicated PCMCIA Card
CVM1-DRM21-V1 or C200HW-
DRM21-V1
Note The CS1W-DRM21, open
network controllers, or NX-
Servers for DeviceNet cannot
be used.
Impossible
Impossible
Impossible
Impossible
Impossible
Impossible
Impossible
Possible
Impossible
Impossible
Possible (extension: .ntf)
Possible
(master: Extension: .dsf
slave: Extension: .dpf)
Impossible
Impossible