Omron 3G8F5-DRM21-E - V2 Operation Manual page 73

Devicenet configurator ver. 2; isa board; pcmcia card
Table of Contents

Advertisement

Connecting to the Network
54
Registration of the connection Dialog Box
Registration
The registration name for the DeviceNet network to be connected is
Name
set here. Up to 20 networks can be set, each up to 25 characters in
length.
Host (PLC)
This is the setting for the Configurator computer.
Information
Network
Address
Node address The user inputs the FINS node address for the com-
Remote Infor-
These are the settings for the DeviceNet Unit and Ethernet Unit that
mation
are used to connect with the DeviceNet network.
DeviceNet
Unit
Ethernet Unit
Setting the Network Address in Host (PLC) Information:
Set the FINS network address for the computer. The computer running the
Configurator uses OMRON's FINS communications service to connect to the
DeviceNet network via Ethernet. Thus, the computer must have not only an IP
address, but also a FINS network address and node address. The relation-
ship between the FINS node address and the IP address is specified by the
address conversion in the Ethernet Unit.
Obtain the FINS node address corresponding to the IP address (See note.) of
the computer from the address conversion of the Ethernet Unit. Refer to Infor-
mation on Address Conversion on page 56 for details.
Setting the Node Address in Host (PLC) Information:
Set the FINS node address for the computer.
Obtain the FINS node address corresponding to the IP address (See note.) of
the computer from the address conversion of the Ethernet Unit. Refer to Infor-
mation on Address Conversion on page 56 for details.
The user inputs the FINS network address for the
computer here. Set the same address as the one set
for the Ethernet Unit. Input 0 if no other address is
going to be set.
puter here.
Network
Input the FINS network address for
Address
the DeviceNet to be connected.
Input if crossing networks past
the direct Ethernet connection. If
not crossing networks, input 0.
Node Address Input the node address for the
DeviceNet to be connected.
crossing networks past the
direct Ethernet connection. If not
crossing networks, input 0.
Unit No.
Input the unit No. of the DeviceNet
to be connected, for use as a CPU
Bus Unit.
Port No.
Input the Fins UDP port No. for the
Ethernet Unit.
IP Address
Input the IP address for the Ethernet
Unit.
Section 3-3
Input if