B002 Power Supply Distribution
60Hz
I
----------------------,
CB1
I
I
I
I
lAC
I
power
TB 1
I
L
6
TB1
Components inside
dotted line are
mounted off power
supply chassis.
11~_N~
__________
~J-5-04--4~
I
I
I
I
I
I
I
I
I
I
I
I
L -_ _ _ _
\
To fan
:
______ -l
L _ _
e
Connector J2
(plug side)
r
800@
0®®@
0®®@
..)
Pin
Description
1
+5 Vdc
2
+24 Vdc
3
+11 Vdc
4
+24 Vdc
5
+11 Vdc
6
+11 Vdc
7
Common
8
Common
9
Common*
10
Common
11
Frame ground
12
Common
*For Model 02R, pin 9 is -12 Vdc.
This diagram is for instructional purposes only.
7-2
SY34-0613
T1
I -
I
I
-1
CD
Connector P1
o
o
G)
Fuse
Fl*
F2
F3
Supply
-12 Vdc
24 Vdc
11 Vdc
Rating
-lA Sio-Blo
lOA Med-Blo
8A Med-Blo
F4
5 Vdc
5A Sio-Blo
8*Fl is installed on model 02R
only.
Voltage
Voltage
Ripple
supply
tolerance
tolerance
+5 Vdc
+4.6 to +5.5
0.15
+11 Vdc
+10.12 to +12.1
0.22
+24 Vdc
+22.08 to +26.4
0.48
J 1 (P1)
Ripple voltage can be measured most accurately
with an oscilloscope. However, an alternate way to
get an indication of ripple voltage is with a CE
meter (PN 1749231).
a. Connect a capacitor (0.22 uF or larger, 50 Vdc
or higher) in series with one of the meter leads.
b. Set the meter to a range that will read 2.5 Vac.
c. Connect one meter lead to the dc voltage in
question, the other lead to frame ground.
(Remember, a capacitor is in series with one
of the leads.)
d. If the meter pointer leaves zero on the meter
scale, excess ripple voltage may be present.