• Disconnect the motor connector.
• Using a pair of pliers, detach the spring that
keeps the tensioner spring under tension.
• Remove the belt from the tensioner belt and
motor axis.
• Loosen the screws that hold the front and rear
motor fastening rods, lift them up by rotating
them and remove them by pulling them off the
rear hook.
• Slightly rotate the whole motor unit.
• Lift it up and remove.

7.12 Rotating compressor running condenser.

• Remove the worktop.
• Remove the right side panel.
• Remove the drum rotating motor.
• Disconnect the 2 connectors.
• Loosen the screw that holds the condenser in its
slot and remove it by pulling it upwards.