Overheating on cooling dissipator for
E5A
Inverter (>88°C)
E5H
Input voltage is lower than 175V.
Input voltage is too high - greater
E5C
than 430V.
Data transfer error between Inverter
E5d
and main PCB
Communication error between
E5E
Inverter and main PCB
E5F
Inverter PCB fails to start the motor
Technical Support - A.D.L.
Full name
 The cycle is suspended
 If it is detected before the cycle starts, the cycle
start will not be permitted.
 The cycle is suspended
 If it is detected before the cycle starts, the cycle
start will not be permitted.
 The cycle is suspended
 If it is detected before the cycle starts, the cycle
start will not be permitted.
 The cycle is suspended
 If it is detected before the cycle starts, the cycle
start will not be permitted.
 The cycle is suspended
 If it is detected before the cycle starts, the cycle
start will not be permitted.
 The cycle is suspended
 If it is detected before the cycle starts, the cycle
start will not be permitted.
Action
56/69
Notes and possible causes
 Overheating caused by continuous operation or
ambient conditions.
 Inverter board faulty.
NTC open (on the Inverter board)
 Faulty wiring.
 Inverter board faulty;
 Input voltage is too high (measure the grid
voltage).
 Inverter board faulty
 Line interference.
 Faulty wiring.
 Main board or Inverter board faulty.
 Faulty wiring between main board and Inverter.
 Inverter board faulty.
 Main board faulty.
 Faulty wiring.
 Inverter board faulty.
 Main board faulty.
599 76 86-51 Rev. 01