7.13 Temperature probe

• Remove the worktop.
• Remove the right side panel.
We recommend you remove the drum rotation motor
to make this operation easier
• Disconnect the probe.
• Remove the probe holding metallic clip (2).
• Pull the probe (1) upwards in order to remove it
from its slot.

7.14 Motor protector

To reach the thermal motor protection, loosen
the screw indicated by the arrow which secures
the protective cap.
The thermal motor protection is located inside it
(indicated by the arrow), kept in contact with the
motor by a spring and the motor contacts.
WARNING
Before disconnecting the electrical wires, make a
note of their position.