Electrolux 599 76 86-51 Service Manual page 60

Condensation tumble dryer with heat pump and steam generator
Table of Contents

Advertisement

Power supply frequency out of range  If detected in setup, it would not be possible cycle
EH1
Power supply voltage out of range
EH2
(too HIGH)
Power supply voltage out of range
EH3
(too LOW)
EH4
Zero Watt relay alarm
EHD
Current leakage alarm
EHE
Safety line alarm
EHF
Safety line sensing alarm
Technical Support - A.D.L.
Full name
starting. If happens during cycle execution, it
suspend working.
 It is automatically cleared when power supply
return within right limits, it would be possible to
start. If a cycle was temporary suspended due to
this alarm it automatically restarts.
 The tumble dryer is working properly but the zero
Watt circuit is never activated.
 The cycle is suspended.
 The cycle is suspended.
 The cycle is suspended.
Action
60/69
Notes and possible causes
 Power Supply Problems
 Wrong MCF
 Main board error
 Power Supply Problems - TOO HIGH VOLTAGE
 Wrong MCF
 Main board error
 Power Supply Problems - TOO LOW VOLTAGE
 Wrong MCF
 Main board error
 Main board faulty.
 Current leakage of any actuator.
 Faulty wiring.
 Main board faulty.
 Main board faulty.
 Main board faulty.