User interface board communication
E91
alarm
Inconsistent user interface board
E92
protocol
E93
MCF checksum alarm
E94
CCF checksum alarm
E97
Missing programme on CTF alarm
E98
Inconsistent inverter board protocol.
E9C
User interface checksum alarm
One or more touchkeys on the user
E9E
interface does not work
Technical Support - A.D.L.
Full name
Action
No action possible
No action possible
The machine could not work until a right
configuration file is programmed
The machine could not work until a right
configuration file is programmed
Only detected when configuration is performed.
Does not allow the cycle to start.
Only detected when configuration is performed.
Does not allow the cycle to start.
No action possible
No action possible
59/69
Notes and possible causes
Faulty wiring.
User interface board faulty.
Main board faulty.
The User Interface board is not compatible with
the Main Board.
Wrong Machine Configuration File
Wrong Cycle Configuration File
Wrong selector configuration (MCF) or missing
cycle on cycle table (CCF)
The User Interface board is not compatible with
the Main Board.
Inverter board faulty.
Bad main board configuration.
Faulty wiring.
Presence of damp on the user interface board.
Board faulty.