7.19 Front panel

• Remove the worktop
• Remove the control panel (you do not need to
disconnect it electrically).
• Loosen the 2 screws securing the appliance door
to the air conduit
• If present, remove the aesthetic cover above the
door block (not shown in the figure) using a
screwdriver.
• Loosen the 3 screws securing the front panel to
the air conduit.
• Loosen the 2 screws on either side securing the
front panel to the air conduit.
• Tilt the front panel slightly forward and lift it.

7.20 Drum light

• Remove the frontal piece.
• Disconnect the connector.
• Slightly press the two clips that hold the drum
lamp and simultaneously push it inwards until it is
completely removed.