8.5 ALARMS TABLE

Condensation water filling pump
E21
alarm
Condensation water filling pump
E22
detection alarm
Conductivity Sensor Frequency too
E31
HIGH
Conductivity Sensor Frequency too
E32
LOW
E45
Door Closed Sensing Alarm
Technical Support - A.D.L.
Full name
 The cycle is suspended.
 If detected during configuration, the cycle start will
not be permitted.
 The cycle is suspended.
 If it is detected before the cycle starts, the cycle
start will not be permitted.
 The cycle is suspended.
 If it is detected before the cycle starts, the cycle
start will not be permitted.
Action
No action.
No action.
54/69
Notes and possible causes
 Pump disconnected (wiring or connector error)
 Pump faulty
 Water filling pump TRIAC error (short-circuit,
diode mode, open circuit) (power board error)
 Pump TRIAC detection circuit error (main board
error)
Only active during diagnostics of the HUMIDITY
SENSOR SHORT-CIRCUIT.
 The oscillation Frequency is out of Range (Main
Board Failure)
Only active during diagnostics of the HUMIDITY
SENSOR SHORT-CIRCUIT.
 The drum is not short-circuited.
 Wiring error.
 The oscillation Frequency is out of Range (Main
Board Failure).
Error in the door closed detection circuit.
 Door micro-switch faulty or disconnected.
 Main board error