Safety Term And Symbol - UNI-T UT8806E User Manual

Desktop digital multimeter
Hide thumbs Also See for UT8806E:
Table of Contents

Advertisement

User's Manual
Warnings
IEC measurement category II includes electrical installations connected to the mains via a
socket on a branch circuit. These devices include most small appliances, test equipment, and
other devices plugged into branch circuit sockets.
Measurement of UT8806E Digital Multimeter
The HI and LO input terminals are connected to the electric mains (up to 300VAC) in these
devices, or to branch circuit socket. However, the HI and LO input terminals of the UT8806E
cannot be connected to the electric mains in permanently installed electrical devices, such as
main breaker panels, sub-panel breakout boxes, or permanently wired motors. These devices
and circuits are susceptible to overvoltage that exceed the protection limits of the UT8806E.
Notes
The voltage above 300VAC can only be measured in circuits that disconnected from the
electric mains. However, transient overvoltage also exist in circuits when disconnected from
the electric mains, and the UT8806E can safely withstand incidental transient overvoltage up
to 2500 Vpk.
Do not use this device to measure circuits where transient overvoltage may exceed this level.

Safety Term and Symbol

Safety Symbol
Instruments.uni-trend.com
It indicates possible danger of electric shock, which may
Danger
cause personal injury or death.
It indicates that you should be careful to avoid personal injury
Warning
or product damage.
It indicates possible danger, which may cause damage to this
device or other equipment if you fail to follow a certain
Caution
procedure or condition. If the "Caution" sign is present, all
conditions must be met before you proceed to operation.
It indicates potential problems, which may cause failure of this
device if you fail to follow a certain procedure or condition. If
Note
the "Note" sign is present, all conditions must be met before
this device will function properly.
AC
Alternating current of device.
DC
Direct current of device
Grounding
Frame and chassis grounding terminal
Grounding
Protective grounding terminal
UT8806E Desktop Digital Multimeter