6. Read the measured results
The reading rate of a frequency measurement depends on the frequency level of the signal
being measured. The multimeter displays the current measurement and the result on the
screen.
7. Mathematical operation
The user can perform mathematical operations (statistic, limit, relative) on measured
readings. For details on how to use this function, refer to the section "Mathematical
Operation Function" in this chapter.
8. Graphical display
The user can change the display mode of the measured data through [Display], and there
are four display modes, "Digital", "Bar", "Tendency" and "Histogram" figures. Please refer to
the section "Display Mode" for details.

Signal Period Measurement

When measuring AC voltage, the user can read the frequency value by turning on the dual
display function; and it can also get the same frequency reading in the frequency
measurement. The connection and test method of signal period measurement will be
described in detail below.
Test Steps
1.
Press the
period measurement menu, as shown in Figure 2-28.
Instruments.uni-trend.com
key on the front panel, and then press the
Figure 0–32 Signal Period Measurement Menu
UT8806E Desktop Digital Multimeter
key to enter the signal
39 / 104