List Of Field Settings For Outdoor-Air Processing Unit; Operation Control Mode - Daikin VRV Aurora RXLQ-TATJU Series Service Manual

Table of Contents

Advertisement

SiUS341802EC
1.6

List of Field Settings for Outdoor-Air Processing Unit

First
Mode
Code
Setting Contents
No.
No.
Filter contamination
0
10
(20)
Display time to clean
3
air filter calculation
External ON/OFF
1
input
12
(22)
Power failure
5
automatic reset
Discharge pipe
temperature
3
(cooling)
14
(24)
Discharge pipe
temperature
4
(heating)
1.7

Operation Control Mode

The operation control mode is compatible with a variety of controls and operations by limiting the
functions of the operation remote controller. Furthermore, operations such as remote controller
ON/OFF can be limited in accordance with the combination conditions. (Refer to information on the
next page.)
Central remote controller is normally available for operations. (Except when centralized monitor is
connected)
Contents of Control Modes
20 modes consisting of combinations of the following 5 operation modes with temperature and
operation mode setting by remote controller can be set and displayed by operation modes 0
through 19.
 ON/OFF control impossible by remote controller
 OFF control only possible by remote controller
 Centralized
 Individual
 Timer operation possible by remote controller
Part 5 Field Settings and Test Operation
Dip switch
B
Heating
Speed Tap
01
02
2500 hr
1250 hr
Display
No
display
Forced
ON/OFF
OFF
control
Equipped
Not
equipped
°C
13
14
°F
55.4
57.2
°C
18
19
°F
64.4
66.2
Used when you want to turn ON/OFF by central remote controller only. (Cannot be turned
ON/OFF by remote controller.)
Used when you want to turn ON by central remote controller only, and OFF by remote controller
only.
Used when you want to turn ON by central remote controller only, and turn ON/OFF freely by
remote controller during set time.
Used when you want to turn ON/OFF by both central remote controller and remote controller.
Used when you want to turn ON/OFF by remote controller during set time and you do not want
to start operation by central remote controller when time of system start is programmed.
A
—
C
D
Second Code No.
03
04
05
06
18
15
16
17
59 60.8 62.6 64.4
66.2 68 69.8 71.6 73.4 75.2
20
21
22
23
68 69.8 71.6 73.4 75.2 77
Field Settings for Indoor Unit
DS3
OFF
—
ON
OFF
ON
07
08
09
10
11
19
20
21
22
23
25
24
26
27
28
78.8 80.6 82.4 84.2
OFF
OFF
ON
ON
: Factory setting
12
13
14
15
24
25
77
29
30
86
170