Daikin VRV Aurora RXLQ-TATJU Series Service Manual page 224

Table of Contents

Advertisement

Troubleshooting by Error Code
Error
Operation
code
lamp
H7
l
H9
l
J3
l
J5
l
J6
l
J7
l
J8
l
J9
l
Outdoor
JA
l
Unit
JC
l
L1
l
L2
l
L3
l
L4
l
L5
l
L8
l
L9
l
LC
l
P1
l
P3
l
P4 (1)
l
PJ
l
U0 (1)
k
U1
l
U2
l
U3
l
U4
l
U5
l
U7
l
U8
l
U9
l
System
UA
l
UC (1)
k
UE
l
UF
l
UH
l
Note(s)
1: The system can keep operating, however, be sure to check and repair.
2: The system may continue operation depending on the conditions.
217
Outdoor fan motor signal abnormality
Outdoor fan PCB abnormality
Outdoor air thermistor (R1T) abnormality
Discharge pipe thermistor (R21T) abnormality
Compressor body thermistor (R14T) abnormality
Compressor suction thermistor (R12T) abnormality
Suction pipe thermistor (R10T) abnormality
Heat exchanger deicer thermistor (R11T) abnormality
Heat exchanger gas pipe thermistor (R8T, R9T) abnormality
Receiver inlet thermistor (R3T) abnormality
Subcooling heat exchanger liquid pipe thermistor (R7T) abnormality
Subcooling injection thermistor (R16T) abnormality
Heat exchanger liquid pipe thermistor (R4T, R5T) abnormality
Leak detection thermistor (R15T) abnormality
Subcooling heat exchanger gas pipe thermistor (R6T) abnormality
Receiver gas purge thermistor (R13T) abnormality
High pressure sensor abnormality
Low pressure sensor abnormality
Inverter PCB abnormality
Momentary power failure during test operation
Reactor temperature rise abnormality
Inverter radiation fin temperature rise abnormality
Compressor instantaneous overcurrent
Compressor overcurrent
Compressor startup abnormality
Transmission error between inverter PCB and outdoor unit main PCB
Power supply voltage imbalance
Reactor surface thermistor abnormality
Inverter radiation fin temperature abnormality
Field setting abnormality after replacing outdoor unit main PCB or combination of PCB
abnormality
Refrigerant shortage
Reverse phase, Open phase
Power supply insufficient or instantaneous abnormality
Check operation not executed
Transmission error between indoor units and outdoor units, Open phase in power
supply wiring
Transmission error between remote controller and indoor unit
Transmission error between outdoor units
Transmission error between main and sub remote controllers
Transmission error between indoor units and outdoor units in the same system
Improper combination of indoor and outdoor units, indoor units and remote controller
Incorrect gas furnace connecting number
Incorrect electric heater capacity setting
Address duplication of centralized controller
Transmission error between centralized controller and indoor unit
System not set yet
System abnormality, refrigerant system address undefined
Climate Talk communication system combination error (before initial setting for
communication completes)
Climate Talk communication system combination error (after initial setting for
communication completes)
Error contents
SiUS341802EC
Reference
page
305
306
307
307
307
307
307
307
307
309
310
311
313
314
315
319
321
323
325
327
329
330
332
333
334
336
338
339
342
343
349
350
351
356
357
358
359
362
363
365
366
Part 6 Service Diagnosis