Daikin VRV Aurora RXLQ-TATJU Series Service Manual page 89

Table of Contents

Advertisement

SiUS341802EC
Forced Defrost
Error Display
Swap Unit No.
Addressed Sensor
Value
1
2
3
4
5
6
Part 3 Remote Controller
Maintenance Menu
Forced defrost ON
Forced defrost OFF
Display error ON
Display error OFF
Display warning ON
Display warning OFF
Current Unit No.
Transfer Unit No.
Unit No.: 0 - 15
Code
00:
01:
02:
03:
04:
05:
06:
07:
08:
09:
30: (4)
31: (4)(5)
32: (4)(5)
33: (4)
34: (4)(5)
35: (4)(6)
Data
(For FXTQ-TA, FXTQ-TB, CXTQ-TA models)
The actual fan speed is converted into the fan tap to be displayed. Therefore, if the fan speed
is changed by controls or external factors, the airflow rate set with the remote controller may
differ from the fan tap display.
(For FXTQ-TA, FXTQ-TB models)
0 rpm is displayed even if the fan is rotating.
(For CXTQ-TA models)
- rpm is displayed even if the fan is rotating.
(For FXTQ-TA, FXTQ-TB, CXTQ-TA models)
The ON/OFF status of the humidifier connected to HUMIDIFIER on the X1M terminal of the
indoor unit PCB is not displayed. The ON/OFF status of the humidifier connected to the
wiring adaptor is displayed.
Only for CXTQ-TA
Displays 99 when it is more than 100%.
Display unit is by 100 CFM.
(ex. Displays 19 for 1850 CFM. Displays 18 for 1849 CFM.)
Service Settings Menu, Maintenance Menu
Item 2
Enables the forced defrost operation.
Disables the forced defrost operation.
Displays the error on the screen.
Displays neither errors nor warnings.
Displays a warning on the screen if an error occurs.
No warning is displayed.
A unit No. can be transferred to another.
Select the unit number you want to check.
Remote controller thermistor (°C)
Suction air thermistor (°C)
Heat exchanger liquid pipe thermistor (°C)
Heat exchanger gas pipe thermistor (°C)
Indoor unit address No.
Outdoor unit address No.
Branch Selector unit address No.
Zone control address No.
Cooling/Heating batch address No.
Demand/low-noise address No.
Displays thermostat step 1 ON/OFF.
Thermostat step 1 OFF: 00
Thermostat step 1 ON: 01
Displays the heat demand that CXTQ-TA is currently
sending to the gas furnace (%).
Displays the fan demand that CXTQ-TA is currently
sending to the gas furnace (%).
Current status of heat pump ON/OFF for CXTQ-TA
HP OFF: 00
HP ON: 01
Current status of gas combustion heating
Displays current heat actual status (%).
Current airflow of the fan
Displays current airflow (CFM).
The corresponding data will be displayed, based on
the unit number and Code selected.
Remarks
82