SiUS341802EC
Model name (Combination unit)
Model name (Independent unit)
Power supply
1 Cooling capacity
Nominal
Rated
2 Heating capacity
Nominal
Rated
Casing color
Dimensions: (H × W × D)
Heat exchanger
Compressor
Type
Displacement
Number of revolutions
Motor output ×
Number of units
Starting method
Fan
Type
Motor output
Airflow rate
Drive
Connecting
Liquid pipe
pipes
Gas pipe
Weight
3 Sound pressure level (Reference data)
3 Sound power level (Reference data)
Safety devices
Defrost method
Capacity control
Refrigerant
Refrigerant name
Charge
Control
Standard accessories
Drawing No.
Notes:
Indoor temp.: 80°FDB (26.7°CDB), 67°FWB (19.4°CWB) / Outdoor temp.: 95°FDB (35.0°CDB) / Equivalent piping length: 50 ft. (15.5 m) for ducted indoor units, 100 ft. (30.5
1.
m) for non-ducted indoor units, level difference: 0 ft. (0 m).
Indoor temp.: 70°FDB (21.1°CDB) / Outdoor temp.: 47°FDB (8.3°CDB), 43°FWB (6.1°CWB) / Equivalent piping length: 50 ft. (15.5 m) for ducted indoor units, 100 ft. (30.5
2.
m) for non-ducted indoor units, level difference: 0 ft. (0 m).
Anechoic chamber conversion value, measured under ISO standard conditions. During actual operation, these values may be higher as a result of ambient conditions.
3.
Sound pressure level may increase during heating operation at ambient temps below 41°F (5°C) value in parenthesis the max sound pressure at those conditions.
4.
Part 1 General Information
RXLQ144TATJU(A)
RXLQ72TATJU(A)
RXLQ72TATJU(A)
3 phase, 208/230 V, 60 Hz
144,000 (42.2)
Btu/h
(kW)
138,000 (40.4)
162,000 (47.5)
Btu/h
(kW)
154,000 (45.1)
Ivory white (5Y7.5/1)
66-11/16 × 48-7/8 × 30-3/16 +
66-11/16 × 48-7/8 × 30-3/16
in (mm)
(1,694 × 1,242 × 767 +
1,694 × 1,242 × 767)
Cross fin coil
Hermetically sealed scroll type
m³/h
12.9 + 12.9
r/min
3,804 + 3,804
kW
4.0 × 1 + 4.0 × 1
Soft start
Propeller fan
kW
(0.80 × 2) × 2
cfm
7,283 + 7,283 (206 + 206)
(m³/min)
Direct drive
 1/2 (12.7) C1220T
in (mm)
(Brazing connection)
 1-1/8 (28.6) C1220T
in (mm)
(Brazing connection)
lbs (kg)
727 + 727 (330 + 330)
dB (A)
63 (68 4)
dB
82
High pressure switch,
Fan driver overload protector,
Overcurrent fuse,
Inverter overload protector,
Leak detecting device
Deicer
%
5.4 ~ 100
R-410A
lbs (kg)
25.8 + 25.8 (11.7 + 11.7)
Electronic expansion valve
Installation manual,
Operation manual,
Connection pipes, Clamps
4D112567A
RXLQ192TATJU(A)
RXLQ96TATJU(A)
RXLQ96TATJU(A)
3 phase, 208/230 V, 60 Hz
192,000 (56.3)
184,000 (53.9)
216,000 (63.3)
206,000 (60.4)
Ivory white (5Y7.5/1)
66-11/16 × 48-7/8 × 30-3/16 +
66-11/16 × 48-7/8 × 30-3/16
(1,694 × 1,242 × 767 +
1,694 × 1,242 × 767)
Cross fin coil
Hermetically sealed scroll type
17.7 + 17.7
3,342 + 3,342
5.1 × 1 + 5.1 × 1
Soft start
Propeller fan
(0.80 × 2) × 2
7,989 + 7,989 (226 + 226)
Direct drive
 5/8 (15.9) C1220T
(Brazing connection)
 1-1/8 (28.6) C1220T
(Brazing connection)
793 + 793 (360 + 360)
64 (70 4)
83.5
High pressure switch,
Fan driver overload protector,
Overcurrent fuse,
Inverter overload protector,
Leak detecting device
Deicer
6.4 ~ 100
R-410A
25.8 + 25.8 (11.7 + 11.7)
Electronic expansion valve
Installation manual,
Operation manual,
Connection pipes, Clamps
4D112568A
Specifications
RXLQ240TATJU(A)
RXLQ120TATJU(A)
RXLQ120TATJU(A)
3 phase, 208/230 V, 60 Hz
240,000 (70.3)
228,000 (66.8)
270,000 (79.1)
256,000 (75.0)
Ivory white (5Y7.5/1)
66-11/16 × 48-7/8 × 30-3/16 +
66-11/16 × 48-7/8 × 30-3/16
(1,694 × 1,242 × 767 +
1,694 × 1,242 × 767)
Cross fin coil
Hermetically sealed scroll type
22.4 + 22.4
4,230 + 4,230
6.5 × 1 + 6.5 × 1
Soft start
Propeller fan
(0.80 × 2) × 2
8,806 + 8,806 (249 + 249)
Direct drive
 5/8 (15.9) C1220T
(Brazing connection)
 1-3/8 (34.9) C1220T
(Brazing connection)
793 + 793 (360 + 360)
67 (70 4)
87.5
High pressure switch,
Fan driver overload protector,
Overcurrent fuse,
Inverter overload protector,
Leak detecting device
Deicer
5.9 ~ 100
R-410A
25.8 + 25.8 (11.7 + 11.7)
Electronic expansion valve
Installation manual,
Operation manual,
Connection pipes, Clamps
4D112569A