Compressor Step Control - Daikin VRV RXYQ72-384XAYCA Service Manual

Heat pump 60 hz
Table of Contents

Advertisement

SiUS342004EB
5.4

Compressor Step Control

The compressor operation varies in the following steps according to information in Compressor PI Control on page 88.
Furthermore, the operating priority of compressors is subject to information in Operating Priority and Rotation of
Compressors on page 89.
Single unit installation
RXYQ72-120XA, RXYQ72-120XB
Step No.
rps
Step No.
1
15.0
2
15.2
3
15.4
4
15.6
5
15.9
6
16.2
7
16.5
8
16.8
9
17.1
10
17.4
11
17.7
12
18.0
13
18.3
14
18.6
15
19.0
16
19.4
17
19.8
18
20.1
19
20.5
20
20.7
21
21.0
22
21.3
23
21.6
24
21.9
25
22.2
26
22.5
27
22.9
28
23.2
29
23.5
30
23.8
31
24.2
32
24.5
33
24.9
34
25.2
35
25.5
36
25.9
37
26.3
38
26.6
39
27.0
40
27.4
100
41
27.8
101
42
28.1
102
43
28.5
103
44
29.0
104
45
29.4
105
46
29.8
106
47
30.2
107
48
30.6
108
49
31.0
109
50
31.5
110
51
31.9
111
52
32.4
112
53
32.8
113
54
33.3
114
55
33.8
115
56
34.2
116
57
34.7
117
58
35.2
118
59
35.7
119
60
36.2
120
Note(s)
1. Depending on the operating conditions of compressors, the compressors may run in patterns
Part 4 Functions and Control
rps
Step No.
61
36.7
121
62
37.2
122
63
37.7
123
64
38.3
124
65
38.8
125
66
39.3
126
67
39.9
127
68
40.5
128
69
41.0
129
70
41.6
130
71
42.2
131
72
42.8
132
73
43.4
133
74
44.0
134
75
44.6
135
76
45.2
136
77
45.8
137
78
46.5
138
79
47.1
139
80
47.8
140
81
48.5
141
82
49.1
142
83
49.8
143
84
50.5
144
85
51.1
145
86
52.0
146
87
52.7
147
88
53.4
148
89
54.2
149
90
54.9
150
91
55.7
151
92
56.5
152
93
57.3
153
94
58.1
154
95
58.9
155
96
59.7
156
97
60.5
157
98
61.4
158
99
62.3
63.4
64.0
64.9
65.6
66.6
67.7
68.6
69.6
70.6
71.6
72.6
73.6
74.6
75.7
76.7
77.8
78.9
80.0
81.1
82.2
83.4
other than those aforementioned.
rps
84.5
85.7
86.9
88.1
89.4
90.6
91.9
93.2
94.5
95.8
97.2
98.5
99.9
101.3
72 class upper limit
102.7
104.2
105.6
107.1
108.4
110.1
111.7
113.2
114.8
116.4
118.0
119.7
96 class upper limit
121.4
123.1
124.8
126.5
128.3
130.1
132.0
133.8
135.7
137.6
139.5
140.0
120 class upper limit
Basic Control
90

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vrv rxyq72-384xbyca