Note:
or kinking.
3. Insert the connector plate onto the bulkhead-mounting bolts with the connectors
positioned as shown.
4. Secure the connector plate to one of the mounting bolts with the flange nut previously
removed.
5. Locate the wire harness on the machine and plug the wire connectors into the wire
connectors of the finishing kit.
6. Repeat this procedure on the remaining 4 bulkhead locations as shown.
The connector plates are positioned differently at the remaining locations so the hose
can be routed through the bulkhead bracket and to the cutting unit without getting
twisted or kinked.
Setup: Mounting the Finishing Kits
When tightening the nuts, use a backup wrench to prevent the hose from twisting
G402739
G402741
IMPORTANT
Page 3–9
Left front cutting unit (#4)
Extra flange nut
Connector plate
Bulkhead bracket
Left rear cutting unit (#2)
Extra flange nut
Connector plate
Bulkhead bracket
3464-478 A