Bleeding the Fuel System

1. Prepare the machine for maintenance.
2. Ensure that the fuel tank is at least half full.
3. Open the hood.
4. Open the air-bleed screw
injection pump.
5. Turn the ignition key to the O
Note:
out around the air-bleed screw.
6. Tighten the screw and turn the ignition key to
the O
FF
7. Close and latch the hood.

Cleaning the Fuel-Pickup Tube Screen

Removing the Fuel-Pickup Tube
The fuel-pickup tube, located inside the fuel tank, is equipped with a screen to help prevent
debris from entering the fuel system. Remove the fuel-pickup tube and clean the screen as
required.
1. Prepare the machine for maintenance.
2. Remove the 5 screws
sender cover
remove the cover.
3464-478A
The electric fuel pump runs, forcing air
position.
that secure the fuel-
to the fuel tank
on the fuel-
position.
N
G439312
, and
G415055
Page 6–22