Priming the Fuel System (continued)
B. Cycle the ignition key to the O
Note:
C. Cycle the key to the O
D. Inspect for leaks around the filter and hoses.
E. Start the engine and inspect for leaks.

Electrical System Maintenance

Inspecting the Electrical Cables

Inspect the electrical cables for damage, wear, loose fittings, weather deterioration, and
chemical deterioration.
Note:

Disconnecting the Battery

Battery electrolyte contains sulfuric acid, which is fatal if consumed and causes
severe burns.
• Do not drink electrolyte and avoid contact with skin, eyes, or clothing.
• Wear safety glasses and rubber gloves.
• Fill the battery where clean water is always available for flushing the skin.
1. Prepare the machine for maintenance.
2. Open the screen.
3464-478A
This allows the ECU to power down.
N
Make all necessary repairs before operating.
position for 30 to 40 seconds.
FF
position for 15 to 20 seconds.
DANGER
Page 6–26
Maintenance: Electrical System Maintenance