50
F I N A L T E S T I N G
Heating up time
1. Plug into mains and press power
button.
Test is passed if power button is turning green
from 25 sec to 40 sec at 230 V mains voltage
or within 60 sec at 100 V / 120 V mains voltage and 50 / 60 Hz mains
frequency.
Flow rate (at 8 bar) / water temperature
1. Insert dummy capsule into capsule
holder.
Service manual
2. Measure the heating up time with a
stop watch (time until power button
stops blinking).
2. Align dummy capsule to needle:
Turn dummy capsule till screw head
(A) fits in dent (B) inside of capsule
holder.