Check 
procedure 
4.1 Machine (with capsule 
holder inserted) is not 
working ­ no function 
4 Plug into mains 
and switch ON 
machine 
4.2 Indicator (LED) flashes red 
3 times a second (error mode) 
4.3 Machine is working 
without capsule holder 
4.4 Machine is hissing after 
heating up. 
Symptoms 
YES ­ a) Check if power cord is 
functional 
YES ­ b) Check if all electrical 
connectors are connected 
YES ­ c) Check if thermoblock's 
thermal cutoff fuses (133 °C) are 
defective 
YES ­ d) Check if power button and 
its indicator (LED) is functional 
YES ­ e) Check if reed contact is 
functional 
YES ­ f) Check if selection lever 
moves freely 
YES ­ g) Check if pump starts to 
work if bargraph display lights up 
and selection lever is moved to the 
left (cold water) 
YES ­ h) Check if pump starts to 
work if bargraph display lights up 
and selection lever is moved to the 
right (hot water) 
YES ­ i) Check if pump's thermal 
cut off fuse (98 °C) is defective 
YES ­ a) Check if NTC temperature 
sensor is functional 
YES ­ b) Check if electrical wires 
are functional 
NO ­ Go to point 4.3 
YES ­ Replace the extraction head 
NO ­ Go to point 4.4 
YES ­ Replace the extraction head 
NO ­ Go to point 5 
T R O U B L E S H O O T I N G 
Action / repair work 
Service manual 
Further action / 
repair work
YES ­ Go to point b) 
NO ­ Replace it (see page 35) 
YES ­ Go to point c) 
NO ­ Connect them (see page 
48) 
YES ­ Replace power cord and 
electronic mainboard. If neces­ 
sary replace also the ther­ 
moblock (see page 58). 
NO ­ Go to point d) 
YES ­ Go to point e) 
NO ­ Replace electronic main­ 
board (see page 58) 
YES ­ Go to point f) 
NO ­ Replace extraction head 
(see page 48) 
YES ­ Go to point g) 
NO ­ Replace locking handle 
(see page 45) 
YES ­ Go to point h) 
NO ­ Replace pump (see page 
30) 
YES ­ Go to point 4.3 
NO ­ Replace the extraction head 
(valve switch might be broken), 
see page 48. If still not working, 
replace also electronic main­ 
board, see page 58. 
YES ­ Replace pump (see page 
30) 
NO ­ Replace pump (see page 
30) or electronic mainboard (see 
page 58) or extraction head (see 
page 48) 
NO ­ Replace NTC temperature 
sensor (see page 34) 
YES ­ Go to point b) 
YES ­ Replace electronic main­ 
board (see page 58) 
NO ­ Replace defective wire(s), 
see page 48 
see page 48 
see page 48 