DeLonghi NESCAFE Dolce Gusto EDG 305 Service Manual page 35

Table of Contents

Advertisement

36 
R E P A I R 
6. Unplug flat receptacles from electronic mainboard (20). 
7. Unplug flat receptacle from pump (21) and thermoblock (9). 
The flat receptacle at the pump has a special connector 
latching. Press down lever at first, then pull receptacle.
8. Replace defect power cord. 