40
R E P A I R
7. Loosen the bayonet catch and remove the thermoblock (9) from the support (10).
Assembly tips
•
Mount new NTC temperature sensor on thermoblock first (see page 34 and
following).
•
Cut hot water pressure hose from extraction head to thermoblock to 35 mm length
according to illustration.
Service manual