5. Remove thermoblock (9) with thermoblock support (10) see large detail:
Release retention latch of support at the base plate with a screwdriver (red circle).
Push hooks beside retention latch in direction shown with a screwdriver and
remove thermoblock support.
6. Loosen screw (18) and remove fuse holder clip (17) with ground connection (p) and
thermo fuses (q) from thermoblock (9).
R E P A I R
Service manual