Speco DVR-4TN Manual page 77

Triplex* digital video recorder family with network/ddns video server
Hide thumbs Also See for DVR-4TN:
Table of Contents

Advertisement

User's Manual
ezDDNS S
ate okl
Host name
C
XXXXXX
Press any key
to return
5.1.7
RS485 Setup
This menu allows the user to setup the parameters of the unit's RS-485
communications port. From the Main menu, select <RS485 Setup> and press
ENTER. The following menu is displayed.
RS485 Setup
1. Unit ID
224
2. Baud Rate
9600
3. Bits
8
4. Stop
4
5. Parity
None
5.1.7.1
Unit ID
This item is used to change the RS-485 ID address of the unit. The ID is with
the range of «1» to «255». The default is <224>.
5.1.7.2
Baud Rate
The Baud rate options for association with the protocol are <2400>, <4800>,
«9600», <19200>, «38400» and «57600». The default is «9600» baud.
5.1.7.3
Bits
The user can specify the bits in a word that are associated with this protocol.
The available options are <6>, <7> and <8> bits. The default is <8> bits.
5.1.7.4
Stop
The user can specify the stop bit associated with this protocol. Options are
«1» and «2» stop bits. The default is <1> stop bit.
DVR-TNIBTNATGTN/ 16TS/6TT Series