Xcc Events Organized By Severity - Lenovo 7X69 Manual

Hide thumbs Also See for 7X69:
Table of Contents

Advertisement

Table 1. Events that automatically notify Support (continued)
Event ID
FQXSPIO0001L
FQXSPIO0011N
FQXSPIO0015M
FQXSPPW0035M
FQXSPPW0047M
FQXSPPW0063M
FQXSPSD0001L
FQXSPSD0002G
FQXSPSD0005L
FQXSPSD0006L
FQXSPSS4004I
FQXSPSS4005I

XCC events organized by severity

The following table lists all XCC events, organized by severity (Information, Error, and Warning).
Table 2. Events organized by severity
Message String
Event ID
FQXSPBR4000I
Management Controller [arg1]: Configuration restored from a file by
user [arg2] from [arg3] at IP address [arg4].
FQXSPBR4002I
Management Controller [arg1] Reset was caused by restoring default
values.
FQXSPBR4004I
Server timeouts set by user [arg1]: EnableOSWatchdog=[arg2],
OSWatchdogTimout=[arg3], EnableLoaderWatchdog=[arg4],
LoaderTimeout=[arg5].
FQXSPBR4005I
Management Controller [arg1]: Configuration saved to a file by user
[arg2].
FQXSPBR4006I
Management Controller [arg1]: Configuration restoration from a file by
user [arg2] completed from [arg3] at IP address [arg4].
FQXSPBR4009I
Management Controller [arg1]: cloning configuration from neighbor
server [arg2] by group name [arg3].
FQXSPBR400AI
Management Controller [arg1]: cloning configuration from neighbor
server [arg2] by group name [arg3] completed.
FQXSPBR400BI
Management Controller [arg1]: cloning configuration from neighbor
server [arg2] by group name [arg3] failed to complete.
Message String
The connector [PhysicalConnectorElementName] has encountered a
configuration error.
An Uncorrectable Error has occurred on [SensorElementName].
Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName].
Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted.
Numeric sensor [NumericSensorElementName] going high (upper critical) has
asserted.
Sensor [SensorElementName] has transitioned to critical from a less severe
state.
The [StorageVolumeElementName] has a fault.
Failure Predicted on [StorageVolumeElementName] for array
[ComputerSystemElementName].
Array [ComputerSystemElementName] is in critical condition.
Array [ComputerSystemElementName] has failed.
Test Call Home Generated by user [arg1].
Manual Call Home by user [arg1]: [arg2].
Severity
Informational
Informational
Informational
Informational
Informational
Informational
Informational
Informational
.
Chapter 2
XClarity Controller events
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinksystem sr8607x70

Table of Contents