4. If the problem persists, collect Service Data logs and contact Lenovo Support.
Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFMA0029I: The PFA of DIMM [arg1] has been deasserted after applying PPR for this DIMM.
[arg2]
Severity: Info
Parameters:
[arg1] DIMM Silk Label, 1-based
[arg2] DIMM info (S/N, FRU and UDI.), e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Information only; no action is required.
• FQXSFMA0030I: A correctable memory error has been detected on DIMM [arg1]. [arg2]
Severity: Info
Parameters:
[arg1] DIMM Silk Label, 1-based
[arg2] DIMM info (S/N, FRU and UDI.), e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Information only; no action is required.
• FQXSFMA0030K: Intel Optane DCPMM [arg1] Percentage Remaining is less than [arg2]% and still
functioning.
Severity: Warning
Parameters:
[arg1] DIMM Silk Label, 1-based
[arg2] Percentage Remaining Threshold
User Action:
Complete the following steps:
1. Check the current Intel Optane DCPMM DIMM health status in one of the following ways:
a. Run DCPMM test under LXPM diagnostic. Look for "Percentage Remaining" of spare blocks.
b. Check for "Remaining Life" of spare blocks on the XCC Web GUI.
2. Back up data.
• FQXSFMA0031K: Intel Optane DCPMM [arg1] has reached 1% remaining spares block and still
functioning.
Severity: Warning
Parameters:
[arg1] DIMM Silk Label, 1-based
User Action:
Complete the following steps:
1. Check the current Intel Optane DCPMM DIMM health status in one of the following ways:
.
171