information only; no action is required.
• FQXSPPW2047I: Numeric sensor [NumericSensorElementName] going high (upper critical) has
deasserted.
This message is for the use case when an implementation has detected an Upper Critical sensor going
high has deasserted.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Voltage
SNMP Trap ID: 1
CIM Prefix: PLAT CIM ID: 0495
User Action:
Information only; no action is required.
• FQXSPPW2057I: Sensor [SensorElementName] has deasserted the transition from normal to non-
critical state.
This message is for the use case when an implementation has detected that a Sensor has deasserted a
transition to non-critical from normal.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - Power
SNMP Trap ID: 164
CIM Prefix: PLAT CIM ID: 0521
User Action:
1. Check power supply LEDs:
2. If AC LED is not lit, check power cord and input voltage.
3. If DC LED is not lit, remove and reinstall power supply.
4. If error LED is lit, replace the power supply.
• FQXSPPW2061I: Sensor [SensorElementName] has transitioned to a less severe state from critical.
This message is for the use case when an implementation has detected a Sensor transition to less severe
from critical.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Power
SNMP Trap ID: 4
CIM Prefix: PLAT CIM ID: 0523
User Action:
Information only; no action is required
• FQXSPPW2063I: Sensor [SensorElementName] has transitioned to a less severe state from critical.
This message is for the use case when an implementation has detected a Sensor transition to less severe
from critical.
Severity: Info
100