Lenovo 7X69 Manual page 157

Hide thumbs Also See for 7X69:
Table of Contents

Advertisement

Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFDD0007G: Security Key Lifecycle Manager (SKLM) IPMI Error.
Severity: Warning
User Action:
Complete the following steps:
1. Check Lenovo Support site for an applicable service bulletin or UEFI firmware update that applies to
this error.
2. A/C cycle the system.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFDD0012I: SATA Hard Drive Error: [arg1] was recovered.
Severity: Info
Parameters:
[arg1] Slot/bay label name in system
User Action:
Information only; no action is required.
• FQXSFDD0012K: SATA Hard Drive Error: [arg1].
Severity: Error
Parameters:
[arg1] Slot/bay label name in system
User Action:
Complete the following steps:
1. Power down the server.
2. Re-insert SATA Drive to ensure it is fully connected to the backplane.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFIO0005M: An intra-board UPI failure has been detected on the link between processor [arg1]
port [arg2] and processor [arg3] port [arg4].
Severity: Error
Parameters:
[arg1] Socket number, 1-based
[arg2] Port Number
[arg3] Socket number, 1-based
[arg4] Port Number
User Action:
Complete the following steps:
1. Power off the system and remove A/C power.
2. Restore A/C power and power on the system.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
.
153
Chapter 3
UEFI events

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinksystem sr8607x70

Table of Contents